SONIMIX 7100
MFC Gas Mixer
The Sonimix 7100 is a gas mixer mainly used to calibrate and linearize gas monitors and to generate specific gas mixtures .
The Sonimix 7100 is based on the principle of gas flow through MFC (Mass Flow Controllers) and is built according the ISO 6145/7 standards. This instrument provides a very high flexibility allowing to combine multigas mixtures (up to 5 gases + a balance gas) and multi-range functionality.
The touch-screen LCD interface provides simple and user-friendly management of all functions on the unit.
All models make automatic calculation in function of the used gases types. The Sonimix 7100 is totally compatible with the US EPA methods and can be easily linked with National Standards (NIST, METAS, UKAS…)
Each mass flow controller is factory calibrated in 10 points by a traceable primary standard.
Product features
- Accuracy – (2% rel.)
- No maintenance
- High dilution range
- Remote control
- Ergonomic with LCD display
Main applications
- Fulfilment of ISO 14481 standards CEM (QUAL 1 to QUAL 3)
- Quality control of gas analysers and sensors
- Gas analysers production
- Interference measurement
Technical specifications
| Models: Sonimix 7100 | Sx 7100 2L1R | Sx 7100 2L2R | Sx 7100 2L3R | Sx 7100 Multi Gas |
| General Data | ||||
| Dilution range | 10 – 100 % | 1 – 100 % | 0,1 – 100 % | – |
| Dilution principle | Mass Flow Controllers | |||
| Dilution gas line flow accuracy | 0.5 % (rel.) + 0,1 FS | |||
| Source gas line flow accuracy | 0.5 % (rel.) + 0,1 FS | |||
| Repeatability on flow | 0.2% (rel.)+ 0,1 FS | |||
| Accuracy on dilution | Better than 2% (rel.) according to ratio dilution | |||
| Warm up time | < 45 min | |||
| Stabilization time | less than 1 min (once the device has warmed up) | |||
| Tightness | < 10-7 mbar l/s verified by He detection | |||
| Operating temperature | 15°C – 40°C | |||
| Dimensions | 19″ 3HE/84 TE , 500mm deep portable casing in option |
|||
| Net weight | 15 – 20 Kg | |||
| Gas inlet requirments | ||||
| Dilution gas: | Requires dry (-40°C DP) Air, Nitrogen or other carrier gas | |||
| Source gas: | Compatible with low corrosive gases | |||
| Pressure | 3 ± 0.3 bar rel | |||
| Fittings | Swagelok 1/4″ | |||
| Gas outlet requirements | ||||
| Flow | 3.5 L/min (other flow rate upon request) | |||
| Pressure | atm + 150 mb max (other pressure upon request) | |||
| Fittings | Swagelok 1/4″ | |||
| Communication | ||||
| RS 232 | Standard | |||
| Ethernet TCP/IP | Standard | |||
| USB | Standard | |||
| Electrical data | ||||
| Power supply voltage | 230V/50-60Hz 115V/60Hz 100V/50-60Hz |
|||
| Installed power (Max) | 65 – 150W | |||
How does the Sonimix 7100 reduce operational costs?
By generating multiple concentrations from one high-concentration gas cylinder. The Sonimix 7100 reduce the number of cylinders required, lowers inventory costs, and simplifies gas logistics.
Which LNI Swissgas solution is best suited for calibrating gas analyzers, gas sensors, or gas detectors?
LNI Swissgas offers several calibration solutions depending on the application.
The Sonimix 2106 and Sonimix 7100 generate accurate gas concentrations through dynamic dilution from gas cylinder. While the Permacal generates trace-level concentrations of reactive compounds such as NH₃, HCl, HF, HBr, VOCs, and hydrocarbons from permeation tubes.
Together, these solutions cover a wide range of gas analyzer, sensor, and gas detector calibration applications.
Why use a gas mixer or a permeation system instead of single gas cylinders?
Permeation systems or gas mixer allow users to generate multiple concentration levels on demand from a single source gas cylinder or permeation tube. This reduces the number of calibration cylinders required, lowers operating costs and simplifies logistics.
They also provide exceptional flexibility for multi-point calibrations and linearity checks. Concentration setpoints can be adjusted quickly and accurately across the analyzer’s, sensors’s or detector’s measurement range, making it easy to verify instrument linearity, response, and performance without changing cylinders.
This saves time while improving calibration efficiency, traceability, and repeatability.
What technology is used (MFC, sonic nozzles, hybrid systems)?
The technology used will depend of the products. In the Sonimix 2106 we use exclusively the Sonic Nozzle to generate a gas mixture. In the Sonimix 7100 we use exclusively MFC’s to generate a gas mixture. In other product we sometime combine both to manage the gas flow.
How many calibration points can it automatically handle for analyzer linearity verification?
Depending of the use technology, we can start from 10 points and go up to an infinite number of points.
Does the system generate static or dynamic gas mixtures?
Our system are dynamic gas mixer.
When is it better to choose a Sonic Nozzle based system over MFC’s?
Sonic Nozzles are significantly more accurate than Mass Flow Controllers (MFCs). The uncertainty of the resulting gas concentration is typically below 0.5% relative, whereas an MFC-based system generally provides an uncertainty of around 1.5% relative.
Sonic Nozzle technology is therefore preferred for applications requiring highly accurate and repeatable gas mixing, particularly in calibration, metrology, specialty gas and UHP applications.
Calibrator or gas mixer: which one should you choose based on your application?
The term “calibrator” is often used when the primary application is the calibration of a gas analyzer or sensor. The term “gas mixer” is more commonly used when the objective is to generate a specific gas mixture.
Generating a gas mixture can serve different purposes, such as supplying an instrument, simulating a process gas, or calibrating an analyzer or sensor. In many cases, a gas mixer and a calibrator are essentially the same device, with the terminology depending mainly on the intended application.
Is it suitable for audit or official regulatory inspection environments?
Yes, all systems can be linked to the national standards.
Does the system require periodic maintenance or frequent recalibration?
The Sonic Nozzle technology provides unmatched stability, resulting in minimal drift and a recommended service interval of two years.
Does the system reduce logistics and gas storage costs?
Yes, our gas mixer helps reduce the number of gas cylinders required. Using a single high-concentration gas cylinder, the gas mixer can generate multiple concentration levels by dilution with a carrier gas.
This reduces the number of cylinders needed, lowers costs, and simplifies the associated logistics and cylinder management.
Can the system operate in continuous mode (24/7)?
Some customer are running our system in their production (24/7), no problem.
Is the system suitable for reactive gases or low concentration ranges?
Yes, thanks to special coatings.
Are gas-contact parts treated to prevent adsorption or contamination?
Yes, we have different type of coating to prevent adsorption/contamination depending of the use gas.
Can it handle high-purity gases without signal degradation?
Yes, coating really help to prevent adsoprtion on the wetted parts which help to avoid contamination.
Does the calibrator generate gases independently or does it dilute certified cylinder gases?
Permeation system are generating trace of gas at ppb level from permeation tubes. Gas mixer are generating mixture from multiple gas cylinder.
Can the system send status signals (Ready/Fault) to the analyzer to synchronize calibration phases?
Yes, there is an autostart function to synchronize the calibrator with an analyzer.
Can solenoid cylinder switching valves be directly controlled via the software?
Yes, all valves within the system are controlled automatically by the software.
Does the software log all events (flows, cylinder changes, errors) to ensure traceability and audit compliance?
Yes, the log allows to track the operational events.
Is it possible to program automatic multi-point calibration sequences?
Yes, all devices include a sequence mode which allows to build a calibration sequence to automatize a calibration process.
Is an accredited calibration certificate provided for the entire system?
LNI Swissgas is accredited according to ISO/IEC 17025 for flow measurement calibrations. An ISO/IEC 17025 calibration certificate can be supplied with every device.
Information request
Need more information about this product?
Please contact us at info@lni-swissgas.eu or fill the form.