SONIMIX 2130
Nox converter tester
The Sonimix 2130 NOx converter tester has been designed to generate a stable NO2 concentration with a small reaction time. It is based on the sonic nozzles technology (ISO 6145-6 technology) and high stability pressure regulators.
The NOx converter tester is often used together with a multi-steps gas divider also based on sonic nozzles and high precision pressure regulators.
In order to validate NOx measurements, the efficiency of the NO2 converter must be higher than 90 %, it is therefore very important to check easily and precisely the efficiency of the NO2 converter.
The SONIMIX 2130 converter tester is based on the process known under the name of Gaseous Phase Titration
Product features
- Easy use and installation
- US EPA Method
Main applications
- Test of the converter’sefficiency
- Emission measurements on the stack monitoring and automotive industry
Technical specifications
| Models: SX 2130 | 6800 50 001 | 6800 50 002 | 6800 50 003 |
| Gas generation | |||
| Concentration | Low | High | |
| NO2 & O3 generation | 15 to 50 ppm | 30 to 100 ppm | 300 to 1000 ppm |
| Inlet pressure | 2,5 to 4 bar rel.(37 to 58 PSI) | ||
| Outlet pressure | Up to 910mbar rel. (13 PSI) | ||
| Gas dilution | 90% of the NO cylinder | ||
| Stabilization time | NO: < 1 min
O3 and NO2 : < 10 min |
NO: < 1 min
O3 and NO2 : < 10 min |
|
| Flow (Air line) | 0,2 Nl/min | ||
| Flow (NO line) | 2 Nl/min | ||
| Connections | 1/4’’ Swagelok | ||
| Materials in contact with gases | NO, O3, NO2: Stainless steel, Teflon, Gold, Silver
Air: Stainless steel, Aluminium, Silver, Brass |
||
| Alimentation | 230V / 50-60 HZ
115V / 60HZ |
||
Calibrator or gas mixer: which one should you choose based on your application?
The term “calibrator” is often used when the primary application is the calibration of a gas analyzer or sensor. The term “gas mixer” is more commonly used when the objective is to generate a specific gas mixture.
Generating a gas mixture can serve different purposes, such as supplying an instrument, simulating a process gas, or calibrating an analyzer or sensor. In many cases, a gas mixer and a calibrator are essentially the same device, with the terminology depending mainly on the intended application.
Is it suitable for audit or official regulatory inspection environments?
Yes, all systems can be linked to the national standards.
Does the system require periodic maintenance or frequent recalibration?
The Sonic Nozzle technology provides unmatched stability, resulting in minimal drift and a recommended service interval of two years.
Does the system reduce logistics and gas storage costs?
Yes, our gas mixer helps reduce the number of gas cylinders required. Using a single high-concentration gas cylinder, the gas mixer can generate multiple concentration levels by dilution with a carrier gas.
This reduces the number of cylinders needed, lowers costs, and simplifies the associated logistics and cylinder management.
Can the system operate in continuous mode (24/7)?
Some customer are running our system in their production (24/7), no problem.
Can solenoid cylinder switching valves be directly controlled via the software?
Yes, all valves within the system are controlled automatically by the software.
Does the software log all events (flows, cylinder changes, errors) to ensure traceability and audit compliance?
Yes, the log allows to track the operational events.
Is it possible to program automatic multi-point calibration sequences?
Yes, all devices include a sequence mode which allows to build a calibration sequence to automatize a calibration process.
Is an accredited calibration certificate provided for the entire system?
LNI Swissgas is accredited according to ISO/IEC 17025 for flow measurement calibrations. An ISO/IEC 17025 calibration certificate can be supplied with every device.
Information request
Need more information about this product?
Please contact us at info@lni-swissgas.eu or fill the form.